TRANSIENT RESPONSE: OUTPUT VOLTAGE RETURNS IN LESS THAN 1 ms MAX.
FOLLOWING A 50% LOAD CHANGE
HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND
INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
HUMIDITY: 10 ~ 90% RH
EFFICIENCY: 60% TYPICAL, AT FULL LOAD
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
OVER LOAD PROTECTION: 130 ~ 150% MAX.
OVER VOLTAGE PROTECTION: +5V
5.5V ~ 7.0V, 3.3V: 3.8V ~ 4.5V
OVER CURRENT PROTECTION: SHORT CIRCUIT
ALARM METHOD: 1. AUDIO ALARM, 2. FAULT LED, 3. POWER DEFECTIVE SIGNAL
EMI NOISE FILTER: AC INPUT LINE FILTER FOR FCC CLASS B ON EACH POWER UNIT ARE AVAILABLE UPON ORDER
SAFETY: UL / CSA / TUV APPROVAL
HOT-SWAPPABLE / HOT-PLUGGABLE CAPABILITY
DIMENSION: 183.0 (D) x 190.00 (W) x 170.0 (H)
REDUNDANCY: BALANCE SHARE LOAD METHOD